Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Control Release ; 366: 170-181, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128885

RESUMO

The Port Delivery System with ranibizumab (PDS) is an innovative intraocular drug delivery system that has the potential to reduce treatment burden in patients with retinovascular diseases. The Port Delivery Platform (PD-P) implant is a permanent, indwelling device that can be refilled in situ through a self-sealing septum and is designed to continuously deliver ranibizumab by passive diffusion through a porous titanium release control element. We present results for the studies carried out to characterize the stability of ranibizumab for use with the PD-P. Simulated administration, in vitro release studies, and modeling studies were performed to evaluate the compatibility of ranibizumab with the PD-P administration components, and degradation and photostability in the implant. Simulated administration studies demonstrated that ranibizumab was highly compatible with the PD-P administration components (initial fill and refill needles) and commercially available administration components (syringe, transfer needle, syringe closure). Subsequent simulated in vitro release studies examining continuous delivery for up to 12 months in phosphate buffered saline, a surrogate for human vitreous, showed that the primary degradation products of ranibizumab were acidic variants. The presence of these variants increased over time and potency remained high. The stability attributes of ranibizumab were consistent across multiple implant refill-exchanges. Despite some degradation within the implant, the absolute mass of variants released daily from the implant was low due to the continuous release mechanism of the implant. Simulated light exposure within the implant resulted in small increases in the relative amount of ranibizumab degradants compared with those seen over 6 months.


Assuntos
Sistemas de Liberação de Medicamentos , Ranibizumab , Humanos , Difusão , Agulhas , Porosidade
2.
Biomaterials ; 104: 87-103, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27449946

RESUMO

Superhydrophobic surfaces are actively studied across a wide range of applications and industries, and are now finding increased use in the biomedical arena as substrates to control protein adsorption, cellular interaction, and bacterial growth, as well as platforms for drug delivery devices and for diagnostic tools. The commonality in the design of these materials is to create a stable or metastable air layer at the material surface, which lends itself to a number of unique properties. These activities are catalyzing the development of new materials, applications, and fabrication techniques, as well as collaborations across material science, chemistry, engineering, and medicine given the interdisciplinary nature of this work. The review begins with a discussion of superhydrophobicity, and then explores biomedical applications that are utilizing superhydrophobicity in depth including material selection characteristics, in vitro performance, and in vivo performance. General trends are offered for each application in addition to discussion of conflicting data in the literature, and the review concludes with the authors' future perspectives on the utility of superhydrophobic biomaterials for medical applications.


Assuntos
Materiais Biocompatíveis/síntese química , Materiais Biomiméticos/química , Interações Hidrofóbicas e Hidrofílicas , Nanocápsulas/química , Tensoativos/química , Água/química , Adsorção , Nanocápsulas/ultraestrutura , Propriedades de Superfície
3.
J Control Release ; 214: 94-102, 2015 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-26210441

RESUMO

Subcutaneous (SC) injection is becoming a more common route for the administration of biopharmaceuticals. Currently, there is no reliable in vitro method that can be used to anticipate the in vivo performance of a biopharmaceutical formulation intended for SC injection. Nor is there an animal model that can predict in vivo outcomes such as bioavailability in humans. We address this unmet need by the development of a novel in vitro system, termed Scissor (Subcutaneous Injection Site Simulator). The system models environmental changes that a biopharmaceutical could experience as it transitions from conditions of a drug product formulation to the homeostatic state of the hypodermis following SC injection. Scissor uses a dialysis-based injection chamber, which can incorporate various concentrations and combinations of acellular extracellular matrix (ECM) components that may affect the release of a biopharmaceutical from the SC injection site. This chamber is immersed in a container of a bicarbonate-based physiological buffer that mimics the SC injection site and the infinite sink of the body. Such an arrangement allows for real-time monitoring of the biopharmaceutical within the injection chamber, and can be used to characterize physicochemical changes of the drug and its interactions with ECM components. Movement of a biopharmaceutical from the injection chamber to the infinite sink compartment simulates the drug migration from the injection site and uptake by the blood and/or lymph capillaries. Here, we present an initial evaluation of the Scissor system using the ECM element hyaluronic acid and test formulations of insulin and four different monoclonal antibodies. Our findings suggest that Scissor can provide a tractable method to examine the potential fate of a biopharmaceutical formulation after its SC injection in humans and that this approach may provide a reliable and representative alternative to animal testing for the initial screening of SC formulations.


Assuntos
Produtos Biológicos/administração & dosagem , Produtos Biológicos/farmacocinética , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/química , Anticorpos Monoclonais/farmacocinética , Bicarbonatos/química , Produtos Biológicos/química , Soluções Tampão , Química Farmacêutica , Diálise , Desenho de Fármacos , Matriz Extracelular/metabolismo , Humanos , Ácido Hialurônico/metabolismo , Injeções Subcutâneas , Linfa/metabolismo , Tela Subcutânea/metabolismo
4.
J Control Release ; 214: 23-9, 2015 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-26160309

RESUMO

Layered superhydrophobic electrospun meshes composed of poly(ε-caprolactone) (PCL) and poly(glycerol monostearate-co-ε-caprolactone) (PGC-C18) are described as a local source of chemotherapeutic delivery. Specifically, the chemotherapeutic agent SN-38 is incorporated into a central 'core' layer, between two 'shield' layers of mesh without drug. This mesh is resistant to wetting of the surface and throughout the bulk due to the pronounced hydrophobicity imparted by the high roughness of a hydrophobic polymer, PGC-C18. In serum solution, these meshes exhibit slow initial drug release over 10days corresponding to media infiltrating the shield layer, followed by steady release over >30days, as the drug-loaded core layer is wetted. This sequence of events is supported by X-ray computed tomography imaging of a contrast agent solution infiltrating the mesh. In vitro cytotoxicity data collected with Lewis Lung Carcinoma (LLC) cells are consistent with this release profile, remaining cytotoxic for over 20days, longer than the unlayered version. Finally, after subcutaneous implantation in rats, histology of meshes with and without drug demonstrated good integration and lack of adverse reaction over 28days. The drug release rates, robust superhydrophobicity, in vitro cytotoxicity of SN-38 loaded meshes, and compatibility provide key design parameters for the development of an implantable chemotherapeutic-loaded device for the prevention of local lung cancer recurrence following surgical resection.


Assuntos
Preparações de Ação Retardada/química , Animais , Antineoplásicos Fitogênicos/administração & dosagem , Antineoplásicos Fitogênicos/uso terapêutico , Camptotecina/administração & dosagem , Camptotecina/análogos & derivados , Camptotecina/uso terapêutico , Carcinoma Pulmonar de Lewis/patologia , Linhagem Celular Tumoral , Sistemas de Liberação de Medicamentos , Interações Hidrofóbicas e Hidrofílicas , Irinotecano , Recidiva Local de Neoplasia/prevenção & controle , Poliésteres , Ratos , Ratos Endogâmicos Lew , Solubilidade , Propriedades de Superfície
5.
Adv Healthc Mater ; 4(11): 1654-7, 2015 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-26097150

RESUMO

Rapid, simple, and inexpensive point-of-care (POC) medical tests are of significant need around the world. The transition between nonwetting and wetted states is used to create instrument-free surface tension sensors for POC diagnosis, using a layered electrospun mesh with incorporated dye to change color upon wetting.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Animais , Ácidos e Sais Biliares/urina , Glicerol/química , Leite/química , Poliésteres/química , Polímeros/química , Tensão Superficial , Tensoativos , Molhabilidade
6.
Adv Healthc Mater ; 2(9): 1204-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23592698

RESUMO

Application of high-intensity focused ultrasound to drug-loaded superhydrophobic meshes affords triggered drug release by displacing an entrapped air layer. The air layer within the superhydrophobic meshes is characterized using direct visualization and B-mode imaging. Drug-loaded superhydrophobic meshes are cytotoxic in an in vitro assay after ultrasound treatment.


Assuntos
Portadores de Fármacos/química , Ultrassom , Antineoplásicos Fitogênicos/química , Antineoplásicos Fitogênicos/toxicidade , Camptotecina/análogos & derivados , Camptotecina/química , Camptotecina/toxicidade , Sobrevivência Celular/efeitos dos fármacos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Irinotecano , Células MCF-7 , Poliésteres/química
7.
Adv Funct Mater ; 23(29): 3628-3637, 2013 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-25309305

RESUMO

Superhydrophobic, porous, 3D materials composed of poly( ε -caprolactone) (PCL) and the hydrophobic polymer dopant poly(glycerol monostearate- co- ε -caprolactone) (PGC-C18) are fabricated using the electrospinning technique. These 3D materials are distinct from 2D superhydrophobic surfaces, with maintenance of air at the surface as well as within the bulk of the material. These superhydrophobic materials float in water, and when held underwater and pressed, an air bubble is released and will rise to the surface. By changing the PGC-C18 doping concentration in the meshes and/or the fiber size from the micro- to nanoscale, the long-term stability of the entrapped air layer is controlled. The rate of water infiltration into the meshes, and the resulting displacement of the entrapped air, is quantitatively measured using X-ray computed tomography. The properties of the meshes are further probed using surfactants and solvents of different surface tensions. Finally, the application of hydraulic pressure is used to quantify the breakthrough pressure to wet the meshes. The tools for fabrication and analysis of these superhydrophobic materials as well as the ability to control the robustness of the entrapped air layer are highly desirable for a number of existing and emerging applications.

8.
Chem Commun (Camb) ; 49(8): 804-6, 2013 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-23235806

RESUMO

This work demonstrates a facile fabrication method to produce superhydrophobic coatings on chemically distinct materials using the electrospraying process. Coatings are mechanically robust, three-dimensional, and formed using a single fabrication step.


Assuntos
Glicerol/análogos & derivados , Poliésteres/química , Estearatos/química , Técnicas Eletroquímicas , Glicerol/química , Interações Hidrofóbicas e Hidrofílicas , Monoglicerídeos , Propriedades de Superfície
9.
J Control Release ; 162(1): 92-101, 2012 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-22684120

RESUMO

In this work we expand upon a recently reported local drug delivery device, where air is used as a degradable component of our material to control drug release (J. Am. Chem. Soc. 2012, 134, 2016-2019). We consider its potential use as a drug loaded strip to provide both mechanical stability to the anastomosis, and as a means to release drug locally over prolonged periods for prevention of locoregional recurrence in colorectal cancer. Specifically, we electrospun poly(ε-caprolactone) (PCL) with the hydrophobic polymer dopant poly(glycerol monostearate-co-ε-caprolactone) (PGC-C18) and used the resultant mesh to control the release of two anticancer drugs (CPT-11 and SN-38). The increase in mesh hydrophobicity with PGC-C18 addition slows drug release both by the traditional means of drug diffusion, as well as by increasing the stability of the entrapped air layer to delay drug release. We demonstrate that superhydrophobic meshes have mechanical properties appropriate for surgical buttressing of the anastomosis, permit non-invasive assessment of mesh location and documentation of drug release via ultrasound, and release chemotherapy over a prolonged period of time (>90 days) resulting in significant tumor cytotoxicity against a human colorectal cell line (HT-29).


Assuntos
Antineoplásicos Fitogênicos/administração & dosagem , Camptotecina/análogos & derivados , Neoplasias Colorretais/tratamento farmacológico , Sistemas de Liberação de Medicamentos/instrumentação , Glicerol/análogos & derivados , Poliésteres/química , Estearatos/química , Antineoplásicos Fitogênicos/farmacologia , Camptotecina/administração & dosagem , Camptotecina/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Glicerol/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Irinotecano , Monoglicerídeos
10.
Biomacromolecules ; 13(2): 406-11, 2012 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-22242897

RESUMO

A limitation to many polymer-based drug delivery systems is the lack of ability to customize a particular polymer composition for tailoring drug release kinetics to a specific clinical application. In this study, we investigated the structure-property effects of conjugating various hydrophobic biocompatible side chains to poly(glycerol-co-caprolactone) copolymers with the goal of achieving prolonged and controlled release of a chemotherapeutic agent. The choice of side chain significantly affected the resulting polymer properties including thermal transitions, relative crystallinity (ΔH(f)), and hydrophobicity. Drug-loaded films cast from solutions of polymer and 10-hydroxycamptothecin demonstrated prolonged release from four to over seven weeks depending upon side chain structure without initial burst release behavior. Use of the stearic acid-conjugated poly(glycerol-co-caprolactone) films afforded substantial anticancer activity in vitro for at least 50 days when exposed to fresh cultures of A549 human lung cancer cells over 24 h intervals, correlating well with the measured drug release kinetics.


Assuntos
Preparações de Ação Retardada/síntese química , Portadores de Fármacos/síntese química , Poliésteres/síntese química , Antineoplásicos Fitogênicos/administração & dosagem , Antineoplásicos Fitogênicos/química , Antineoplásicos Fitogênicos/farmacologia , Camptotecina/administração & dosagem , Camptotecina/análogos & derivados , Camptotecina/química , Camptotecina/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Preparações de Ação Retardada/química , Portadores de Fármacos/química , Humanos , Interações Hidrofóbicas e Hidrofílicas , Cinética , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia , Espectroscopia de Ressonância Magnética , Tamanho da Partícula , Poliésteres/química , Propriedades de Superfície
11.
J Am Chem Soc ; 134(4): 2016-9, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22279966

RESUMO

We have prepared 3D superhydrophobic materials from biocompatible building blocks, where air acts as a barrier component in a porous electrospun mesh to control the rate at which drug is released. Specifically, we fabricated poly(ε-caprolactone) electrospun meshes containing poly(glycerol monostearate-co-ε-caprolactone) as a hydrophobic polymer dopant, which results in meshes with a high apparent contact angle. We demonstrate that the apparent contact angle of these meshes dictates the rate at which water penetrates into the porous network and displaces entrapped air. The addition of a model bioactive agent (SN-38) showed a release rate with a striking dependence on the apparent contact angle that can be explained by this displacement of air within the electrospun meshes. We further show that porous electrospun meshes with higher surface area can be prepared that release more slowly than control nonporous constructs. Finally, the entrapped air layer within superhydrophobic meshes is shown to be robust in the presence of serum, as drug-loaded meshes were efficacious against cancer cells in vitro for >60 days, thus demonstrating their applicability for long-term drug delivery.


Assuntos
Materiais Biocompatíveis/química , Portadores de Fármacos/química , Sistemas de Liberação de Medicamentos , Ar , Materiais Biocompatíveis/síntese química , Portadores de Fármacos/síntese química , Interações Hidrofóbicas e Hidrofílicas , Tamanho da Partícula , Poliésteres/química , Porosidade , Propriedades de Superfície
12.
Biomaterials ; 29(13): 2033-48, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18289663

RESUMO

Adsorption of lysozyme (Lys), human serum albumin (HSA), and immunoglobulin G (IgG) to anion- and cation-exchange resins is dominated by electrostatic interactions between protein and adsorbent. The solution-depletion method of measuring adsorption shows, however, that these proteins do not irreversibly adsorb to ion-exchange surfaces, even when the charge disparity between adsorbent and protein inferred from protein pI is large. Net-positively-charged Lys (pI=11) and net-negatively-charged HSA (pI=5.5) adsorb so strongly to sulfopropyl sepharose (SP; a negatively-charged, strong cation-exchange resin, -0.22 mmol/mL exchange capacity) that both resist displacement by net-neutral IgG (pI=7.0) in simultaneous adsorption competition experiments. By contrast, IgG readily displaces both Lys and HSA adsorbed either to quaternary ammonium sepharose (Q; a positively-charged, strong anion exchanger, +0.22 mmol/mL exchange capacity) or to octadecyl sepharose (ODS; a neutral hydrophobic resin, 0 mmol/mL exchange capacity). Thus it is concluded that adsorption results do not sensibly correlate with protein pI and that pI is actually a rather poor predictor of affinity for ion-exchange surfaces. Adsorption of Lys, HSA, and IgG to ion-exchange resins from stagnant solution leads to adsorbed multi-layers, into or onto which IgG adsorbs in adsorption competition experiments. Comparison of adsorption to ion-exchange resins and neutral ODS leads to the conclusion that the apparent standard free-energy of adsorption Delta Gads( degrees ) of Lys, HSA, and IgG is not large in comparison to thermal energy due to energy-compensating interactions between water, protein, and ion-exchange surfaces that leaves a small net Delta Gads( degrees ). Thus water is found to control protein adsorption to a full range of substratum types spanning hydrophobic (poorly water wettable) surfaces, hydrophilic surfaces bearing relatively-weak Lewis acid/base functionalities that wet with (hydrogen bond to) water but do not exhibit ion-exchange properties, and surfaces with strong Lewis acid/base functional groups that exhibit ion-exchange properties in the conventional chemistry sense of ion-exchange.


Assuntos
Imunoglobulina G/química , Muramidase/química , Albumina Sérica/química , Adsorção , Humanos , Imunoglobulina G/isolamento & purificação , Íons/química , Muramidase/isolamento & purificação , Albumina Sérica/isolamento & purificação , Soluções , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...